Secondary links

Custom Search 1

Home automation 1-channel alarm transmitter

The 44..ABTA device is a 1-channel alarm transmitter with two inputs, one (IN input) always active and the second one (RESET) can be used only for some of the programmable operating modes. This device enables the user to detect the status of the IN input, send an alarm message (for example a “bathroom call”) and at the same time control a 44..ABR1 or 44..ABR2 receiver for optical/luminous signal, if any).

Technical data
• Enclosure: 1 System 44 module (22.5 w x 45 h x 46.5 d) mm
• Protection degree: IP41 if completed with plate and installed in the corresponding flush-mounting support.
• Reference temperature and relative humidity: 25°C RH 65%
• Operating amb. temp. range: -10°C to +50°C • Maximum Relative Humidity: 90% at 35°C
• Max. Height: 2000 m a.s.l.
• Auxiliary power supply
Voltage rating: 12Vac/dc
Allowed variation: 10.5V ÷ 14V Electrical input at 12Vdc: 2.2 mA MAX Electrical input at 12Vac: 5.8 mA MAX

Connections
• Terminal 1: BUS positive
• Terminal 2: BUS GND
• Terminal 3: auxiliary power supply positive • Terminal 4: auxiliary power supply GND
• Terminal 5: IN input
• Terminal 6: RESET input
 
Description of the front side
One optical signal is visible on the front side indi- cating the operating and programming status of the device.

Home automation alarm transmitter

Function
Function 1: BINARY INPUT
Function 2: N.O. input without memory with sending of ALARM command
Function 3: N.O. input without memory with sending of ON command
Function 4: N.O. input without memory with sending of OFF command
Function 5: N.O. input without memory with sending of STEP command
Function 6: N.O. input without memory with sending of ON+OFF command
Function 7: N.C. input without memory with sending of ALARM command
Function 8: N.C. input without memory with sending of ON command
Function 9: N.C. input without memory with sending of OFF command
Function 10: N.C. input without memory with sending of STEP command
Function 11: N.C. input without memory with sending of ON+OFF command
Function 12: N.O. input with memory with sending of ALARM command
Function 13: N.O. input with memory with sending of ON command
Function 14: N.O. input with memory with sending of OFF command
Function 15: N.O. input with memory with sending of STEP command
Function 16: N.O. input with memory with sending of ON+OFF command
Function 17: N.C. input with memory with sending of ALARM command
Function 18: N.C. input with memory with sending of ON command
Function 19: N.C. input with memory with sending of OFF command
Function 20: N.C. input with memory with sending of STEP command
Function 21: N.C. input with memory with sending of ON+OFF command
Parameter 1
Address 00 - Sending of configured command to the same address of the device
Address 01..FF - Sending of configured command to the set address

Search